17
Safety Precautions
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Do not store or install the Servo Drive in the following locations:
•
Location subject to direct sunlight
•
Location where the ambient temperature exceeds the specified level
•
Location where the relative humidity exceeds the specified level
•
Location subject to condensation due to rapid temperature changes
•
Location subject to corrosive or flammable gases
•
Location subject to high levels of dust, salt content, or iron dust
•
Location subject to splashes of water, oil, chemicals, etc.
•
Location where the Servo Drive may receive vibration or impact directly
Installing or storing the Servo Drive in these locations may result in fire, electric shock, or
equipment damage.
The magnetic attraction force always affects between the Motor Coil Unit and Magnet Track
even when the power supply is turned OFF. Design a machine which supports the
magnetic attraction force and provides enough rigidity to maintain the accuracy.
Malfunction or failure may result.
Design a machine with consideration of the magnetic attraction force.
Malfunction or failure may result.
Do not hit the Motor Coil Unit against the stopper. Design the configuration so that the table
mounted on the Motor Coil Unit hits against the stopper.
Equipment damage may result.
Do not apply strong impact on the product.
Failure may result.
Prevent adhesion of foreign objects to the product.
Malfunction may result.
You cannot use the Linear Motor because its magnetic pole cannot be detected in an
unbalanced load such as vertical axis.
If the magnetic pole cannot be detected, an error may occur and the Linear Motor may be in
the free-run status.
Injury or equipment damage may result.
The protective structure of the Linear Motor is IP00. Take necessary measures to prevent
dust, oil, etc.
Failure may result.
Ensure that the Linear Slider has a sufficient rigidity.
Equipment damage or malfunction may result.
Provide appropriate safety measures to prevent crashes, etc. if you design a system which
cooperates multiple motor coil units such as multi-head or tandem.
Equipment damage may result.
Do not bring electronic devices, magnetic recording media, or other articles that may be
affected by magnetism (clocks, computers, measuring instruments, magnetic cards, IC
cards, etc.) near the linear motor.
This may cause malfunctioning or equipment damage.
Caution
Содержание R88D-KN01H-ECT-L
Страница 136: ...3 Specifications 3 60 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 190: ...4 System Design 4 54 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 208: ...5 EtherCAT Communications 5 18 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 226: ...6 Basic Control Functions 6 18 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 268: ...7 Applied Functions 7 42 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 276: ...8 Safety Function 8 8 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 616: ...Appendices A 170 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 617: ...Index 1 I G5 series Linear Motors Servo Drives With Built in EtherCAT Communications Index...
Страница 624: ......
Страница 625: ......