The BRR setting is found from the following formulas.
Asynchronous mode:
N =
ø
64
×
2
2n–1
×
B
×
10
6
– 1
Clocked synchronous mode:
N =
ø
8
×
2
2n–1
×
B
×
10
6
– 1
Where B: Bit rate (bit/s)
N: BRR setting for baud rate generator (0
≤
N
≤
255)
ø: Operating frequency (MHz)
n: Baud rate generator input clock (n = 0 to 3)
(See the table below for the relation between n and the clock.)
SMR Setting
n
Clock
CKS1
CKS0
0
ø
0
0
1
ø/4
0
1
2
ø/16
1
0
3
ø/64
1
1
The bit rate error in asynchronous mode is found from the following formula:
Error (%) = {
ø
×
10
6
(N + 1)
×
B
×
64
×
2
2n–1
– 1
} ×
100