654
•
Reception
Receive operation should be stopped (by clearing RE to 0) before making a module stop mode,
software standby mode, watch mode, subactive mode, or subsleep mode transition. RSR,
RDR, and SSR are reset. If a transition is made without stopping operation, the data being
received will be invalid.
To continue receiving without changing the reception mode after the relevant mode is cleared,
set RE to 1 before starting reception. To receive with a different receive mode, the procedure
must be started again from initialization.
Figure 16-28 shows a sample flowchart for mode transition during reception.
Read TEND flag in SSR
TE= 0
Transition to software
standby mode, etc.
Exit from software
standby mode, etc.
Change
operating mode?
No
All data
transmitted?
TEND = 1
Yes
Yes
Yes
<Transmission>
No
No
[1]
[3]
[2]
TE= 1
Initialization
<Start of transmission>
[1] Data being transmitted is interrupt-
ed. After exiting software standby
mode, etc., normal CPU transmis-
sion is possible by setting TE to 1,
reading SSR, writing TDR, and
clearing TDRE to 0, but note that if
the DTC has been activated, the
remaining data in DTCRAM will be
transmitted when TE and TIE are
set to 1.
[2] If TIE and TEIE are set to 1, clear
them to 0 in the same way.
[3] Includes module stop mode, watch
mode, subactive mode, and sub-
sleep mode.
Figure 16-25 Sample Flowchart for Mode Transition during Transmission
Содержание H8S/2631
Страница 28: ...xviii Appendix G Package Dimensions 1154 ...
Страница 341: ...316 Transfer SAR or DAR DAR or SAR Block area First block Nth block Figure 9 8 Memory Mapping in Block Transfer Mode ...
Страница 918: ...905 ø DREQ0 DREQ1 tDRQS tDRQH Figure 25 19 DMAC DREQ Input Timing ...
Страница 955: ...943 A 2 Instruction Codes Table A 2 shows the instruction codes ...