431
Conversion Instructions
Section 3-12
Operand Specifications
Description
BINL(058) converts the 8-digit BCD data in S and S+1 to 8-digit hexadecimal
(32-bit binary) data and writes the result to R and R+1.
Flags
Examples
The following diagram shows an example of 8-digit BCD-to-binary conversion.
When CIO 000000 is ON in the following example, the 8-digit BCD value in
CIO 0010 and CIO 0011 is converted to hexadecimal and stored in D00200
and D00201.
Area
S
R
CIO Area
CIO 0000 to CIO 6142
Work Area
W000 to W510
Holding Bit Area
H000 to H510
Auxiliary Bit Area
A000 to A958
A448 to A958
Timer Area
T0000 to T4094
Counter Area
C0000 to C4094
DM Area
D00000 to D32766
EM Area without bank
E00000 to E32766
EM Area with bank
En_00000 to En_32766
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Constants
---
Data Registers
---
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
R
R+1
(BCD)
(BCD)
S+1
S
(BIN)
(BIN)
Name
Label
Operation
Error Flag
ER
ON if the contents of S+1, S are not BCD.
OFF in all other cases.
Equals Flag
=
ON if the result is 0.
OFF in all other cases.
Negative Flag
N
OFF
×
10
3
×
10
2
×
10
1
×
10
0
×
16
3
×
16
2
×
16
1
×
16
0
×
10
7
×
10
6
×
10
5
×
10
4
×
16
7
×
16
6
×
16
5
×
16
4
R+1
R