![Omron CJ1G-CPUxx Instructions Manual Download Page 849](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_742491849.webp)
828
Basic I/O Unit Instructions
Section 3-23
3-23-2 7-SEGMENT DECODER: SDEC(078)
Purpose
Converts the hexadecimal contents of the designated digit(s) into 8-bit, 7-seg-
ment display code and places it into the upper or lower 8-bits of the specified
destination words.
Ladder Symbol
Variations
Applicable Program Areas
Operands: Digit Designator
Operand Specifications
S: Source word
Di: Digit designator
D: First destination word
SDEC(078)
S
Di
D
Variations
Executed Each Cycle for ON Condition
SDEC(078)
Executed Once for Upward Differentiation
@SDEC(078)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Not supported.
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
First digit of S to convert (0 to 3)
0: Digit 0 (bits 0 to 3 of S)
1: Digit 1 (bits 4 to 7 of S)
2: Digit 2 (bits 8 to 11 of S)
3: Digit 3 (bits 12 to 15 of S)
Number of digits to convert
0 to 3: 1 to 4 digits
First half of D to receive converted data
0: Rightmost 8 bits (1st half)
1: Leftmost 8 bits (2nd half)
Not used; set to 0.
0 1/0 m n
15 12 11 8 7 4 3 0
Di
Area
S
Di
D
CIO Area
CIO 0000 to CIO 6143
Work Area
W000 to W511
Holding Bit Area
H000 to H511
Auxiliary Bit Area
A000 to A959
A448 to A959
Timer Area
T0000 to T4095
Counter Area
C0000 to C4095
DM Area
D00000 to D32767
EM Area without bank
E00000 to E32767
EM Area with bank
En_00000 to En_32767
(n = 0 to C)
Summary of Contents for CJ1G-CPUxx