![Omron CJ1G-CPUxx Instructions Manual Download Page 1070](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_7424911070.webp)
1049
Task Control Instructions
Section 3-34
Specifying an Earlier Task
When CIO 000000 is ON in the following example, task number 1 is made
executable in task number 3. Task number 1 will be executed in the next cycle
when program execution reaches task number 1.
3-34-2 TASK OFF: TKOF(821)
Purpose
Puts the specified cyclic task or extra cyclic task into standby status, i.e., dis-
ables execution of the task. (Extra cyclic tasks are supported by CS1-H, CJ1-
H, and CJ1M CPU Units only.)
Ladder Symbol
Variations
Applicable Program Areas
Operands
N: Task number
The allowed range for N depends on the kind of task being specified.
• Cyclic tasks:
N must be a constant between 0 and 31 decimal. (Values 0 to 31 specify
cyclic tasks 0 to 31.)
• Extra cyclic tasks (CS1-H, CJ1-H, and CJ1M CPU Units only):
N must be a constant between 8000 and 8255 decimal. (Values 8000 to
8255 specify extra cyclic tasks 0 to 255.)
Task number 1 is executed
in the next cycle.
Task 1
Task 3
N: Task number
TKOF(821)
N
Variations
Executed Each Cycle for ON Condition
TKOF(821)
Executed Once for Upward Differentiation
@TKOF(821)
Executed Once for Downward Differentiation
Not supported.
Immediate Refreshing Specification
Not supported.
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
Not allowed