653
Table Data Processing Instructions
Section 3-17
3-17-12 SUM: SUM(184)
Purpose
Adds the bytes or words in the range and outputs the result to two words.
Ladder Symbol
Variations
Applicable Program Areas
C: D00100
C+1: D00101
R1:
–2
–1
–3
D: D00300
PC memory
address
Decimal
equivalent
Min. value
Number of words
10 words
Always 0.
1: Outputs address to IR00.
1: Treats data as signed binary.
1
R1
100CF
000100CF
0
0
0
A
C: First control word
R1: First word in range
D: First destination word
SUM(184)
C
R1
D
Variations
Executed Each Cycle for ON Condition
SUM(184)
Executed Once for Upward Differentiation
@SUM(184)
Executed Once for Downward Differentiation Not supported.