![Omron CJ1G-CPUxx Instructions Manual Download Page 478](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_742491478.webp)
457
Conversion Instructions
Section 3-12
3-12-12 COLUMN TO LINE: LINE(063)
Purpose
Converts a column of bits from a 16-word range (the same bit number in 16
consecutive words) to the 16 bits of the destination word.
Ladder Symbol
Variations
Applicable Program Areas
Operands
S: First Source Word
Specifies the first source word. S and S+15 must be in the same data area.
N: Bit Number
Specifies the bit number (0000 to 000F or &0 to &15) to be copied from the
source words.
S: D00100
D: D00300
Number of bytes (2 bytes)
Starting digit (digit 1)
Parity bits: Result in even parity
Not changed
Not changed
Conversion
Parity: Even
Starting byte: rightmost
Starting digit in D: Digit 1
Number of bytes: 2
Starting byte in S: Rightmost
S: First source word
N: Bit number
D: Destination word
LINE(063)
S
N
D
Variations
Executed Each Cycle for ON Condition
LINE(063)
Executed Once for Upward Differentiation
@LINE(063)
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
Not supported
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK