![Omron CJ1G-CPUxx Instructions Manual Download Page 121](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_742491121.webp)
100
Instruction Functions
Section 2-2
2-2-32 Task Control Instructions
Instruction
Mnemonic
Code
Symbol/Operand
Function
Location
Execution
condition
Page
TASK ON
TKON
@TKON
820
Output
Required
TASK OFF
TKOF
@TKOF
821
Output
Required
N: Task number
TKON(820)
N
The specified task's task number
is higher than the local task's task
number (m<n).
The specified task's task number
is lower than the local task's task
number (m>n).
Task m
Task n
Becomes
execut-
able in
that cycle.
Task m
Task n
Be-
comes
execut-
able in
the next
cycle.
Makes the specified task executable.
N: Task number
TKOF(821)
N
The specified task's task num-
ber is higher than the local
task's task number (m<n).
The specified task's task num-
ber is lower than the local
task's task number (m>n).
Task m
Task n
In stand-
by status
that
cycle.
Task m
Task n
In stand-
by status
the next
cycle.
Puts the specified task into standby status.
Summary of Contents for CJ1G-CPUxx