508
Special Math Instructions
Section 3-14
Linear Extrapolation (C: Word Address)
Using Floating-point Data (CS1-H/CJ1-H/CJ1M Only)
In this example, APR(069) is used to convert the fluid height in a tank to fluid
volume based on the shape of the holding tank.
C+1
C+2
C+3
C+4
C+5
C+6
C+7
C+8
C+ (4n+1)
C+ (4n+2)
C+ (4n+3)
C+ (4n+4)
C+ (4m+1)
C+ (4m+2)
C+ (4m+3)
C+ (4m+4)
X
0
Y
0
Y
m
X
m
R
R+1
S
S+1
0
APR
C
S
R
000000
Fluid height = X
Fluid volume
= Y
Fluid height to volume
conversion table
(Floating-point data)
Y data range:
−∞
,
−
3.402823
×
10
38
to
−
1.175494
×
10
−
38
,
1.175494
×
10
−
38
to
3.402823
×
10
38
, or +
∞
Y: Fluid volume
X: Fluid height
Linear extrapolation of table
The linear extrapolation can
provide a smooth, high-resolution
curve floating-point data is used.
High-resolution
floating point data
X data range:
−∞
,
−
3.402823
×
10
38
to
−
1.175494
×
10
−
38
,
1.175494
×
10
−
38
to 3.402823
×
10
38
, or +
∞
X0 (rightmost 16 bits)
X0 (leftmost 16 bits)
Y0 (rightmost 16 bits)
Y0 (leftmost 16 bits)
X1 (rightmost 16 bits)
X1 (leftmost 16 bits)
Y1 (rightmost 16 bits)
Y1 (leftmost 16 bits)
to
Xn (rightmost 16 bits)
Xn (leftmost 16 bits)
Yn (rightmost 16 bits)
Yn (leftmost 16 bits)
to
Xm (rightmost 16 bits)
Xm (leftmost 16 bits)
Ym (rightmost 16 bits)
Ym (leftmost 16 bits)
to
to