961
Other Instructions
Section 3-31
Note The +(400), +L(401), +B(404), +BL(405), –(410), –L(411), –B(414), and
–BL(415) instructions do no include the Carry Flag in their addition and sub-
traction operations. In general, use these instructions when performing addi-
tion or subtraction.
3-31-3 SELECT EM BANK: EMBC(281)
Purpose
Changes the current EM bank.
Ladder Symbol
Variations
Applicable Program Areas
Operands
N: EM Bank Number
Specifies the new EM bank number in hexadecimal (0000 to 000C).
Operand Specifications
N: EM bank number
EMBC(281)
N
Variations
Executed Each Cycle for ON Condition
EMBC(281)
Executed Once for Upward Differentiation
@EMBC(281)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Not supported.
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
Area
N
CIO Area
CIO 0000 to CIO 6143
Work Area
W000 to W511
Holding Bit Area
H000 to H511
Auxiliary Bit Area
A000 to A959
Timer Area
T0000 to T4095
Counter Area
C0000 to C4095
DM Area
D00000 to D32767
EM Area without bank
E00000 to E32767
EM Area with bank
En_00000 to En_32767
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
Constants
#0000 to #000C (binary)
Data Registers
DR0 to DR15
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)