![Omron CJ1G-CPUxx Instructions Manual Download Page 851](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_742491851.webp)
830
Basic I/O Unit Instructions
Section 3-23
7-segment Data
The following table shows the data conversions from a hexadecimal digit (4
bits) to 7-segment code (8 bits).
Hexadecimal to 7-segment data conversion
(F
71, 1
06, and 2
5B)
S: D00100
D:
Di: 0100
Di
3
Original data
Converted code (segments)
Display
Original data
Digit
Bits
–
g
f
e
d
c
b
a
Hex
0
0
0
0
0
0
0
1
1
1
1
1
1
3F
1
0
0
0
1
0
0
0
0
0
1
1
0
06
2
0
0
1
0
0
1
0
1
1
0
1
1
5B
3
0
0
1
1
0
1
0
0
1
1
1
1
4F
4
0
1
0
0
0
1
1
0
0
1
1
0
66
5
0
1
0
1
0
1
1
0
1
1
0
1
6D
6
0
1
1
0
0
1
1
1
1
1
0
1
7D
7
0
1
1
1
0
0
1
0
0
1
1
1
27
8
1
0
0
0
0
1
1
1
1
1
1
1
7F
9
1
0
0
1
0
1
1
0
1
1
1
1
6F
A
1
0
1
0
0
1
1
1
0
1
1
1
77
B
1
0
1
1
0
1
1
1
1
1
0
0
7C
C
1
1
0
0
0
0
1
1
1
0
0
1
39
D
1
1
0
1
0
1
0
1
1
1
1
0
5E
E
1
1
1
0
0
1
1
1
1
0
0
1
79
F
1
1
1
1
0
1
1
1
0
0
0
1
71
1
1
1
1
1
1
1
0
g
f
b
c
d
e
a
a
b
c
d
e
f
g
LSB
MSB
Summary of Contents for CJ1G-CPUxx