![Omron CJ1G-CPUxx Instructions Manual Download Page 683](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_742491683.webp)
662
Table Data Processing Instructions
Section 3-17
3-17-15 STACK DATA READ: SREAD(639)
Purpose
Reads the data from the specified data element in the stack. The offset value
indicates the location of the desired data element (how many data elements
before the current pointer position).
This instruction is supported by the CS1-H, CJ1-H, CJ1M, and CS1D CPU
Units only.
Ladder Symbol
Variations
Applicable Program Areas
Operands
TB through TB+3: Stack control words
The first four words of the stack contain the PLC memory address of the last
word in the stack and the stack pointer (the PLC memory address of the next
available word in the stack.)
SREAD(639)
TB
C
D
TB: First stack address
C: Offset value
D: Destination word
Variations
Executed Each Cycle for ON Condition
SREAD(639)
Executed Once for Upward Differentiation
@SREAD(639)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Not supported.
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
TB
0
15
TB+1
0
15
TB+2
0
15
TB+3
0
15
PLC memory address of the last
word in the stack (rightmost 4 digits)
PLC memory address of the last
word in the stack (leftmost 4 digits)
Stack pointer (rightmost 4 digits)
(Initial value is the rightmost 4 digits
of the PLC memory address for
Stack pointer (leftmost 4 digits)
(Initial value is the leftmost 4 digits of
the PLC memory address for TB+4.)