![Omron CJ1G-CPUxx Instructions Manual Download Page 222](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_742491222.webp)
201
Sequence Control Instructions
Section 3-5
3-5-7
FOR-NEXT LOOPS: FOR(512)/NEXT(513)
Purpose
The instructions between FOR(512) and NEXT(513) are repeated a specified
number of times. FOR(512) and NEXT(513) are used in pairs.
Ladder Symbols
Variations
Applicable Program Areas
Operands
N: Number of Loops
The number of loops must be 0000 to FFFF (0 to 65,535 decimal).
CIO 000000
ON
CIO 000000
OFF
Normal
execution
Instructions
processed
as
NOP(000).
(Outputs re-
main un-
changed.)
N: Number of loops
FOR(512)
N
NEXT(513)
Variations
Executed Each Cycle for ON Condition
FOR(512)
Executed Each Cycle for ON Condition
NEXT(513)
Immediate Refreshing Specification
Not supported
Block program areas
Step program areas
Subroutines
Interrupt tasks
Not allowed
OK
OK
OK