![Omron CJ1G-CPUxx Instructions Manual Download Page 444](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_742491444.webp)
423
Symbol Math Instructions
Section 3-11
3-11-26 DOUBLE UNSIGNED BINARY DIVIDE: /UL(433)
Purpose
Divides 8-digit (double-word) unsigned hexadecimal data and/or constants.
Ladder Symbol
Variations
Applicable Program Areas
Operand Specifications
Dd: 1st dividend word
Dr: 1st divisor word
R: 1st result word
/UL(433)
Dd
Dr
R
Variations
Executed Each Cycle for ON Condition
/UL(433)
Executed Once for Upward Differentiation
@/UL(433)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Not supported.
Block program
areas
Step program
areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
Area
Dd
Dr
R
CIO Area
CIO 0000 to CIO 6142
CIO 0000 to
CIO 6140
Work Area
W000 to W510
W000 to W508
Holding Bit Area
H000 to H510
H000 to H508
Auxiliary Bit Area
A000 to A958
A448 to A956
Timer Area
T0000 to T4094
T0000 to T4092
Counter Area
C0000 to C4094
C0000 to C4092
DM Area
D00000 to D32766
D00000 to
D32764
EM Area without bank
E00000 to E32766
E00000 to
E32764
EM Area with bank
En_00000 to En_32766
(n = 0 to C)
En_00000 to
En_32764
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Constants
#00000000 to
#FFFFFFFF
(binary)
#00000001 to
#FFFFFFFF
(binary)
---
Data Registers
---
Summary of Contents for CJ1G-CPUxx
Page 3: ...iv N o t i c e ...
Page 5: ...vi ...
Page 21: ...xxii Conformance to EC Directives 6 ...
Page 35: ......
Page 1131: ...1110 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...