![Omron CJ1G-CPUxx Instructions Manual Download Page 1015](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_7424911015.webp)
994
Block Programming Instructions
Section 3-32
3-32-6 ONE CYCLE AND WAIT (NOT): WAIT(805)/WAIT(805) NOT
Purpose
Stops execution of the rest of the block program until an execution condition
turns ON or an operand bit turns ON or OFF.
Ladder Symbol
Variations
Applicable Program Areas
Note WAIT(805)/WAIT(805) NOT must be used in block programming regions even
within subroutines and interrupt tasks.
Operand Specifications
CIO 000001 ON
Block ended
CIO 000003 and
CIO 000004 ON
Block ended
CIO 000001 OFF
CIO 000003 or
CIO 000004 OFF
0
2
B: Bit operand
WAIT(805)
WAIT(805) B
WAIT(805) NOT
B
Variations
Always Executed in Block Program
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
Area
B
CIO Area
CIO 000000 to CIO 614315
Work Area
W00000 to W51115
Holding Bit Area
H00000 to H51115
Auxiliary Bit Area
A00000 to A44715
A44800 to A95915
Timer Area
T0000 to T4095
Counter Area
C0000 to C4095
Task Flags
TK0000 to TK0031
Condition Flags
ER, CY, >, =, <, N, OF, UF, >=, <>, <=ON, OFF, AER
Clock Pulses
0.02 s, 0.1 s, 0.2 s, 1 s, 1 min
DM Area
---