![Omron CJ1G-CPUxx Instructions Manual Download Page 330](http://html1.mh-extra.com/html/omron/cj1g-cpuxx/cj1g-cpuxx_instructions-manual_742491330.webp)
309
Data Shift Instructions
Section 3-9
3-9-1
SHIFT REGISTER: SFT(010)
Purpose
Operates a shift register.
Ladder Symbol
Variations
Applicable Program Areas
Note St and E must be in the same data area.
Operand Specifications
St: Starting word
E: End word
SFT(010)
St
E
Data input
Shift input
Reset input
Variations
Executed Each Cycle for ON Condition
SFT(010)
Executed Once for Upward Differentiation
Not supported
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
Not supported
Block program areas
Step program areas
Subroutines
Interrupt tasks
Not allowed
OK
OK
OK
Area
St
E
CIO Area
CIO 0000 to CIO 6143
Work Area
W000 to W511
Holding Bit Area
H000 to H511
Auxiliary Bit Area
A448 to A959
Timer Area
---
Counter Area
---
DM Area
---
EM Area without bank
---
EM Area with bank
---
Indirect DM/EM
addresses in binary
---
Indirect DM/EM
addresses in BCD
---
Constants
---
Data Registers
---
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15