3-31-4 EXTEND MAXIMUM CYCLE TIME: WDT(094)
Purpose
Extends the maximum cycle time, but only for the cycle in which the instruc-
tion is executed. WDT(094) can be used to prevent errors for long cycle times
when a longer cycle time is temporarily required for special processing.
Ladder Symbol
Variations
Applicable Program Areas
Operands
T: Timer Setting
Specifies the watchdog timer setting between 0000 and 0F9F hexadecimal or
between &0000 and &3999 decimal.
Operand Specifications
Description
WDT(094) extends the maximum cycle time for the cycle in which this instruc-
tion is executed. The watchdog timer setting in the PLC Setup is extended by
an interval of T
×
10 ms (0 to 39,990 ms).
T: Timer setting
WDT(094)
T
Variations
Executed Each Cycle for ON Condition
WDT(094)
Executed Once for Upward Differentiation
@WDT(094)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Not supported.
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
Area
T
CIO Area
---
Work Area
---
Holding Bit Area
---
Auxiliary Bit Area
---
Timer Area
---
Counter Area
---
DM Area
---
EM Area without bank
---
EM Area with bank
---
Indirect DM/EM
addresses in binary
---
Indirect DM/EM
addresses in BCD
---
Constants
0000 to 0F9F (binary)
Data Registers
---
Index Registers
---
Indirect addressing
using Index Registers
---