928
Clock Instructions
Section 3-28
3-28-5 CLOCK ADJUSTMENT: DATE(735)
Purpose
Changes the internal clock setting to the setting in the specified source words.
Note The internal clock setting can also be changed from a Peripheral Device or
the CLOCK WRITE FINS command (0702).
Ladder Symbol
Variations
Applicable Program Areas
Operands
S through S+3: New Clock Setting
Set the new clock setting in S through S+3 as shown in the following diagram.
S through S+3 must be in the same data area.
S: First source word
DATE(735)
S
Variations
Executed Each Cycle for ON Condition
DATE(735)
Executed Once for Upward Differentiation
@DATE(735)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Not supported.
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
Minutes: 00 to 59 (BCD)
Seconds: 00 to 59 (BCD)
Day: 01 to 31 (BCD)
Hour: 00 to 23 (BCD)
Year: 00 to 99 (BCD)
Month: 01 to 12 (BCD)
Always set to 00.
Day of the week: 00 = Sunday
01 = Monday
02 = Tuesday
03 = Wednesday
04 = Thursday
05 = Friday
06 = Saturday
15
8
0
7
S
15
8
0
7
S+1
15
8
0
7
S+2
15
8
0
7
S+3