Block Programming Instructions
Section 3-32
Variations
Applicable Program Areas
Note EXIT(806) and EXIT NOT(806) must be used in block programming regions
even within subroutines and interrupt tasks.
Operand Specifications
Description
Operation without an Operand
EXIT(806) can be executed without an operand. If it is, then an execution con-
dition must be created for it starting with LD. If the execution condition is OFF,
the rest of the block program will be executed normally. If the execution condi-
tion is ON, the rest of the instructions in the block program through
BEND(801) will not be executed.
Variations
Always Executed in Block Program
EXIT(806)
EXIT(806)
B
EXIT NOT(806) B
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
Area
B
CIO Area
CIO 000000 to CIO 614315
Work Area
W00000 to W51115
Holding Bit Area
H00000 to H51115
Auxiliary Bit Area
A00000 to A44715
A44800 to A95915
Timer Area
T0000 to T4095
Counter Area
C0000 to C4095
Task Flags
TK0000 to TK0031
Condition Flags
ER, CY, >, =, <, N, OF, UF, >=, <>, <=, ON, OFF, AER
Clock Pulses
0.02 s, 0.1 s, 0.2 s, 1 s, 1 min
DM Area
---
EM Area without bank
---
EM Area with bank
---
Indirect DM/EM
addresses in binary
---
Indirect DM/EM
addresses in BCD
---
Constants
---
Data Registers
---
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15