340
Data Shift Instructions
Section 3-9
Description
SRD(075) shifts data between St and E by one digit (4 bits) to the right. “0” is
placed in the leftmost digit (bits 15 to 12 of E), and the content of the rightmost
digit (bits 3 to 0 of St) is lost.
Flags
Precautions
When St is greater than E, an error will be generated and the Error Flag will
turn ON.
When SRD(075) is executed, the Equals Flag and Negative Flag will turn
OFF.
Note When large amounts of data are shifted, the instruction execution time is quite
long. Always take care that the power is not cut while SRD(075) is being exe-
cuted, causing the shift operation to stop halfway through.
Auxiliary Bit Area
A448 to A959
Timer Area
T0000 to T4095
Counter Area
C0000 to C4095
DM Area
D00000 to D32767
EM Area without bank
E00000 to E32767
EM Area with bank
En_00000 to En_32767
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Constants
---
Data Registers
---
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Area
St
E
Lost
E
S
t
Name
Label
Operation
Error Flag
ER
ON when St is greater than E.
OFF in all other cases.