651
Table Data Processing Instructions
Section 3-17
R1: First word in range
R1 specifies the first word in the search range. The words from R1 to R1+(C–
1) are searched for the minimum value. (C is the number of words specified in
C.)
Note R1 and R1+C–1 must be in the same data area.
Operand Specifications
8000
Signed binary
No
C000
Signed binary
Yes
C+1
Data type
Index Register output
Search range
R1
R1+(C–1)
15
0
---
to
Area
C
R1
D
CIO Area
CIO 0000 to
CIO 6142
CIO 0000 to CIO 6143
Work Area
W000 to W510
W000 to W511
Holding Bit Area
H000 to H510
H000 to H511
Auxiliary Bit Area
A000 to A958
A000 to A959
A448 to A959
Timer Area
T0000 to T4094
T0000 to T4095
Counter Area
C0000 to C4094
C0000 to C4095
DM Area
D00000 to
D32766
D00000 to D32767
EM Area without bank
E00000 to
E32766
E00000 to E32767
EM Area with bank
En_00000 to
En_32766
(n = 0 to C)
En_00000 to En_32767
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D0000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Constants
Specified values
only
---
Data Registers
---
DR0 to DR15
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15