737 MAX Flight Crew Operations Manual
Normal Procedures -
Amplified Procedures
MN-FLT-OH-201
NP.21.19
GALLEY power switch (as installed) - ON
STANDBY POWER switch - Guard closed
Verify that the STANDY PWR OFF light is extinguished.
Verify that the BAT DISCHARGE light is extinguished.
Verify that the TR UNIT light is extinguished.
Verify that the ELEC light is extinguished.
Generator drive DISCONNECT switches - Guards closed
Verify that the DRIVE lights are illuminated.
BUS TRANSFER switch - Guard closed
Verify that the TRANSFER BUS OFF lights are extinguished.
Verify that the SOURCE OFF lights are extinguished.
Verify that the GEN OFF BUS lights are illuminated.
Lavatory SMOKE light (as installed) .................Verify extinguished
EQUIPMENT COOLING switches ....................................... NORM
Verify that the OFF lights are extinguished.
EMERGENCY EXIT LIGHTS switch ......................... Guard closed
Verify that the NOT ARMED light is extinguished.
Passenger signs ............................................................................. Set
NO SMOKING switch (as installed) - ON
FASTEN BELTS switch - OFF
If the APU is running:
-MAX8 Fleet Only
Verify that the APU DOOR light is extinguished.
Verify that the APU LOW OIL PRESSURE light is extinguished.
Verify that the APU FAULT light is extinguished.
Verify that the APU OVERSPEED light is extinguished.
Windshield WIPER selectors ................................................... PARK
Verify that the windshield wipers are stowed.
Note:
do not operate the wipers on a dry windshield.