B-8 Page 2 of 2
MN-FLT-OH-201
Flight Crew Operations Manual Bulletin No. GOT-8 , Dated May 10, 2018 (continued)
Operating Instructions
After starter cutout speed is reached:
If the START VALVE OPEN alert blinks momentarily then extinguishes, no
flight crew or maintenance action is needed.
If the START VALVE OPEN alert continues to blink for up to 10 seconds then
illuminates steady, do the START VALVE OPEN Non-Normal Checklist.