737 MAX Flight Crew Operations Manual
Hydraulics
Chapter 13
Controls and Indicators
Section 10
MN-FLT-OH-201
13.10.1
10 Controls and Indicators
Controls and Indicators
File Highlight
Hydraulic Panel
1
Electric Hydraulic Pump OVERHEAT Lights
Illuminated (amber) – Hydraulic fluid used to cool and lubricate the
corresponding electric motor driven pump has overheated or the pump itself has
overheated.
2
Hydraulic Pump LOW PRESSURE Lights
Illuminated (amber) – output pressure of associated pump is low.
Note:
When an engine fire switch is pulled, the low pressure light is deactivated.
3
ELECTRIC HYDRAULIC PUMPS Switches
ON – provides power to associated electric motor–driven pump.
OFF – electrical power removed from pump.
4
ENGINE HYDRAULIC PUMPS Switches
ON – de–energizes blocking valve in pump to allow pump pressure to enter
system.
Note:
Should remain ON at shutdown to prolong solenoid life.
OFF – energizes blocking valve to block pump output.
OFF
ON
OFF
ON
B
ELEC 1 ENG 2
ELEC 2
ENG 1
A
HYD PUMPS
PRESSURE
LOW
PRESSURE
LOW
PRESSURE
LOW
PRESSURE
LOW
OVERHEAT
OVERHEAT
FORWARD OVERHEAD PANEL
4
3
1
2