Setup & Operation 12. Option Units
RC180 Rev.17
75
12.2.5 Output Circuit
Rated Output Voltage
: +12 V to 24 V
±
10%
Maximum Output Current
: TYP 100 mA/1 output
Output Driver
: PhotoMOS Relay
On-State Resistance (average) : 23.5
Ω or less
Two types of wiring are available for use with the nonpolar photoMOS relay in the output
circuit.
Protected Expansion I/O Board
Typical Output Circuit Application 1
10 Output No.64
11 Output No.65
12 Output No.66
13 Output No.67
14 Output No.68
15 Output No.69
27 Output No.70
28 Output No.71
17 Output
No.64 to 71 common
Expansion I/O-1
(Same)
Omit
+DC
29 Output
No.72
30 Output
No.73
33 Output
No.72 to 79 common
Load
GND
L
L
(Same)
(Same)
(Same)
(Same)
(Same)
(Same)
(Same)
(Same)