No.
Message
Remedy
Note 1
Note 2
2516
Failed to obtain the debug data or to
initialize.
Reboot the controller.
2517
Failed to convert into date or time.
Check the time set on the controller.
Reboot the controller.
2518
Larger number was specified for the
start point data than the end point data .
Specify a larger number for the end point
data than that for the start point data.
Start point
End point
2519
Specified the format for FmtStr$ can
not understand.
Check the format.
2520
Point file name is too long.
Check whether the specified point file
name is correct. The maximum string
length of the file name is 32.
2521
Point failure. Point file path is too
long.
Check whether the specified point file
name is correct.
2522
Point file name is invalid.
Make sure you don’t use improper
characters for file name.
2523
The continue process was already
executed.
Review the program.
2524
Cannot execute Xqt when the specified
trap number is already executing.
Review the program.
2525
Password is invalid.
Check whether a password is set
correctly.
2526
No wait terms.
Rebuild the project.
2527
Too many variables used for global
valiable wait.
Review the program.
2528
The variables cannot use global
valiable wait.
Review the program.
2529
Cannot use Byref if the variables used
for global variable wait.
Review the program.
2530
Too many point files.
Check the point file.
2531
The point file is used by another robot.
Review the program.
2532
Cannot calculate the point position
because there is undefined data.
Check the point data.
2533
Error on INP or OUTP.
Review the program.
2534
No main function to start on Restart
statement.
Without executing main function, Restart
is called.
2535
Does not allow Enable setting in Teach
mode to be changed.
Setup the authority.
2536
Failed to change Enable setting in
Teach mode.
Reboot the Controller.
2539
Password is invalid.
Check whether a password is set
correctly.
2546
Cannot turn on the motor immediately
after opening the safeguard.
Wait 1.5 seconds after the safeguard is
open, and then execute the motor on.
2550
Specified command is not supported
for joint type robot.
Specified robot is not supported.
Check the robot configuration.
2551
Failed to Get the health information.
Reboot the controller.
2900
Failed to open as server to the Ethernet
port.
Check whether the Ethernet port is set
properly. Check whether the Ethernet
cable is connected properly.
2901
Failed to open as client to the Ethernet
port.
Check whether the Ethernet port is set
properly. Check whether the Ethernet
cable is connected properly.
2902
Failed to read from the Ethernet port.
Check whether the port of
communication recipient is not close.
2904
Invalid IP Address was specified.
Review the IP address.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...