PROFIBUS DP Specifications
Item
Specification
Name
PROFIBUS-DP board
Code
R12B040707
Connection Method
Hybrid
(token passing procedure and master-slave communication)
Baud Rates (bps)
9.6k, 19.2k, 45.45k, 93.75k, 187.5k, 500k,
1.5 M, 3 M, 6 M, 12 M
Transfer Distance
Baud Rates
Cable Length
12M (bps)
6M (bps)
3M (bps)
1.5M (bps)
500k (bps)
187.5k (bps)
93.75k (bps)
45.45k (bps)
19.2k (bps)
9.6k (bps)
100 m
100 m
100 m
200 m
400 m
1000 m
1200 m
1200 m
1200 m
1200 m
Maximum Stations
126 (including master unit and repeater)
Data Length / Frame 244 bytes
Cable
2-wire cable dedicated to PROFIBUS (2 wires for signal)
Modes
Slave
Interface
1 PROFIBUS-DP port (EN 50170)
Output
Current Capacity
Maximum 150 mA
Input Data Size
256 bits (32 bytes)
Output Data Size
256 bits (32 bytes)
Appearance of PROFIBUS-DP
Status Display LED
Address Configure Switch (
×
1)
Address Configure Switch (
×
10)
Terminator Switch
PROFIBUS-DP Connector
O
F
F
L
IN
E
O
NL
INE
E
RRO
R
ONLINE LED
: Online status display
OFFLINE LED
: Offline status display
ERROR LED
: Error status display
Refer to the following table for
functions of LED.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...