Maintenance 8. Trouble Shooting
RC180 Rev.17
176
No.
Message
Remedy
Note 1
Note 2
1160
MCD failure. Failed to open the MCD
file.
Restore the controller configuration.
1161
MCD failure. Failed to read the MCD
file.
Restore the controller configuration.
1163
MCD failure. Failed to save the MCD
file.
Restore the controller configuration.
1165
MPD failure. Failed to open the MPD
file.
1166
MPD failure. Failed to read the MPD
file.
1168
MPD failure. Failed to save the MPD
file.
1170
MPL failure. Failed to open the MPL
file.
1.
Reboot the controller.
2.
Reinstall the firmware.
1181
PRM failure. Failed to replace the
PRM file.
1.
Reboot the controller.
2.
Reconfigure the robot.
1185
File failure. Failed to open the backup
information file.
1186
File failure. Failed to read the backup
information file.
1187
File failure. Failed to write the backup
information file.
1188
File failure. Failed to save the backup
information file.
1189
The backup data was created by an old
version.
Cannot
restore the controller
configuration in the specified procedure
for using old backup data. Check the
backup data.
1190
The backup data was created by a
newer version.
1191
There is no project in the backup data.
1195
File failure. Failed to map the
health history.
Reboot the controller.
-
-
1196
File failure. Failed to open the
health history file.
Reboot the controller.
-
-
1197
File failure. Failed to write the
health history file.
Reboot the controller.
-
-
1200
Compile failure.
Check the compile message.
This error occurs during compilation
from TP. Correct where the error
occurred.
1201
Link failure.
Check the link message.
This error occurs during compilation
from TP. Correct where the error
occurred.
1500
Communication error.
1501
Command did not complete in time.
Execute the command again after a
while. Check the connection between
the PC and controller.
1502
Communication disconnection
between PC and Controller.
Re-establish communication.
Check the connection between the PC
and controller.
1503
Disconnection while executing a task.
Check the connection between the
console device and controller.
1510
Out of IP Address range.
Check the IP address setting of the
controller.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...