Setup & Operation 12. Option Units
90
RC180 Rev.17
CC-Link Specifications
Item
Specification
Name
CC-Link board
Code
R12B040708
Connection Method
Broadcast polling
Baud Rates (bps)
156k, 625k, 2.5M, 5M, 10M
Transfer Distance
Baud Rates
Cable Length
10M (bps)
5M (bps)
2.5M (bps)
625k (bps)
156k (bps)
100 m
160 m
400 m
900 m
1200 m
Maximum Device Volume 64 units
Cable
Dedicated cable supporting CC-Link Ver.1.10
Modes
Slave
Interface
1 CC-Link V1 port
Occupied stations
3 station fixed
Input Data Size
256 bits (96 bits + 10 words)*
Output Data Size
256 bits (96 bits + 10 words)*
* 16 bits of each system inputs and outputs are reserved. Open data size for user is as
follows.
Inputs/Outputs: 80 bits
+
10 words
Appearance of CC-Link
Status Display LED
Station Configure Switch (
×
1)
Station Configure Switch (
×
10)
Baud Rate Configure Switch
CC-Link Connector
RD
E
RRL
SD
RUN
ERRL LED : Error status display
RUN LED : Offline status display
RD LED
: Data reception status
display
SD LED
: Data transmission
status display
Refer to the following table for
LED functions.
LED Description of CC-Link
LED status represents the status of the fieldbus I/O board.
LED status
ERRL RED
RUN GRN
RD GRN
SD GRN
OFF
Normal operation
Device power supply
OFF
Offline
Device power supply
OFF
No data reception
Device power supply
OFF
No data transmission
Device power supply
OFF
ON
CRC error: station
Address error
Baud rate
configuration error
Normal operation
Data reception
Data transmission
Blinking
−
−
−
−
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...