4.4.2 Restore from Teach Pendant TP1 (Option)
CAUTION
■
Make sure that the data used for restore was saved previously for same
Controller.
■
Do not edit the backup files. Otherwise, operation of the robot system after data
restoration to the Controller is not assured.
Restores system files backed up in USB memory to the Controller. (Only TP1. TP2
does not support this function.)
(1)
Insert the USB memory into the Controller.
(2)
In the [Program Mode] screen, move the cursor to [7 System Restore...], and press
the <OK> key.
(3)
The following screen appears.
When you restore the robot name, serial number, and the calibration data with the basic
Controller settings, move the cursor to [Robot name, serial #, calibration] and press the
<
→
> key.
When you restore the project with the basic Controller settings, move the cursor to
[Project] and press the <
→
> key.
(4)
Press the <OK> key
(5)
The following screen appears. Press the <OK> key.