Maintenance 4. Backup and Restore
130
RC180 Rev.17
4.4 Restore
Restore the Controller status from the Teach Pendant (Option) or EPSON RC+ 5.0.
4.4.1 Restore from EPSON RC+ 5.0
CAUTION
■
Make sure that the data used for restore was saved previously for same
Controller.
■
Do not edit the backup files. Otherwise, operation of the robot system after data
restoration to the Controller is not assured.
(1)
Select the EPSON RC+ 5.0 menu-[Tools]-[Controller] to display the [Controller
Tools] dialog.
(2)
Click the <Restore Controller…> button to display the [Browse For Folder] dialog.
(3)
Specify the folder that contains the backup data. Backup data folders are named
using the following format:
B_serial number_date status was saved
→
Example: B_12345_200608074410
Data saved with the Controller status storage function can also be specified for
restore.
Specify the following folder.
S_serial number_data status was saved
→
Example: S_12345_200608074410
NOTE