Maintenance 8. Trouble Shooting
RC180 Rev.17
191
No.
Message
Remedy
Note 1
Note 2
2269
Language ID is out of available range.
For available language ID, see the online
help. Review the program.
The specified
language ID
2270
Specified D parameter value at the
parallel process is out of available
range.
Available D parameter value is from 0 to
100. Review the program.
The specified D
parameter value
2271
Arch number is out of available range.
Available arch number is from 0 to 7.
Review the program.
The specified
arch number
2272
Device No. is out of available range.
The specified number representing a
control device or display device is out of
available range. For available device
number, see the online help. Review
the program.
The specified
device number
2273
Output data is out of available range.
Available output data value is from 0 to
255. Review the program.
Output data
What number
byte data is
out of range?
2274
Asin argument is out of available
range. Range is from -1 to 1.
Review the program.
2275
Acos argument is out of available
range. Range is from -1 to 1.
Review the program.
2276
Sqr argument is out of available range. Review the program.
2277
Randomize argument is out of
available range.
Review the program.
2278
Sin, Cos, Tan argument is out of
available range.
Review the program.
2280
Timeout period set by the TMOut
statement expired before the wait
condition was completed in the WAIT
statement.
Investigate the cause of timeout. Check
whether the set timeout period is proper.
Timeout period
2281
Timeout period set by TMOut
statement in WaitSig statement or
SyncLock statement expired.
Investigate the cause of timeout. Check
whether the set timeout period is proper.
Signal number
Timeout
period
2282
Timeout period set by TMOut
statement in WaitNet statement
expired.
Investigate the cause of timeout. Check
whether the set timeout period is proper.
Port number
Timeout
period
2283
Timeout.
Timeout at display device setting.
Reboot the controller.
2290
Cannot execute a motion command.
Cannot execut the motion command after
using the user function in the motion
command. Review the program.
2291
Cannot execute the OnErr command.
Cannot execute OnErr in the motiion
command when using user function in
the motion command. Review the
program.
2292
Cannot execute an I/O command while
the safeguard is open. Need Forced.
I/O command cannot be executed while
the safeguard is open. Review the
program.
2293
Cannot execute an I/O command
during emergency stop condition. Need
Forced.
I/O command cannot be executed during
emergency stop condition. Review the
program.
2294
Cannot execute an I/O command when
an error has been detected. Need
Forced.
I/O command cannot be executed while
an error occurs. Review the program.
2295
Cannot execute this command from a
NoEmgAbort Task.
For details on inexecutable commands,
refer to the online help.
Review the program.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...