Setup & Operation 3. Installation
RC180 Rev.17
25
3.3 Power Supply
3.3.1 Specifications
Ensure that the available power meets following specifications.
Item
Specification
Voltage
200 VAC to 240 VAC
Phase
Single phase
Frequency
50/60 Hz
Momentary Power
Interrupt
10 ms Or less
Power Consumption
Max. 2.5 kVA
Actual consumption depends on the model, motion, and load
of the Manipulator.
For approximate power consumption of each model, refer to
the followings.
C3 : 1.2 kVA
S5 : 1.2 kVA
G1 : 0.5 kVA
G3 : 1.1 kVA
G6 : 1.5 kVA
G10 : 2.4 kVA
G20 : 2.4 kVA
RS3 : 1.2 kVA
RS4 : 1.4 kVA
Refer to Manipulator manual for Manipulator rated
consumption.
Peak Current
When power is turned ON : approximately 150 A (2 ms.)
When motor is ON :approximately 60 A (5 ms.)
Leakage Current
Max. 10 mA
Ground Resistance
100
Ω
or less
Install an earth leakage circuit breaker or a circuit breaker in the AC power cable line at
15 A or less rated electric current. Both should be a two-pole disconnect type. If you
install an earth leakage circuit breaker, make sure to use an inverter type that does not
operate by induction of a 10 kHz or more leakage current. If you install a circuit
breaker, please select one that will handle the above mentioned “peak current”.
The power receptacle shall be installed near the equipment and shall be easily accessible.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...