Maintenance 6. Maintenance Parts Replacement Procedures
RC180 Rev.17
153
6.3.3 Replacing the Motor Driver (Axis 5 and 6)
Motor Driver
(Axis 5 and 6)
Remove
(1) Turn OFF the Controller and unplug the power connector.
(2) Open the front cover.
Refer
: Maintenance 6.3.2 Replacing Motor Driver (Axis 1 to 4)
Removing procedure from (2) to (7)
(3) Remove the four screws shown to
remove the top cover of the ProSix
Driver Unit.
ProSix
Driver Unit
(4) Remove two screws to remove the
Motor Driver mounting bracket.
Motor Driver
5: Axis 5
6: Axis 6
5
6
Motor Driver
Mounting
Bracket
(5) Secure the two thumb head screws
removed in step (2) to the Motor Driver
heat sink as shown.
(6) Pull out the Motor Driver by pulling the
two thumb head screws together evenly.
CAUTION
■
Be careful not to cut your fingers.
The Motor Driver connector may be connected tightly. The connector may be
disconnected suddenly by a strong pull and may cause your finger to be cut by
the Motor Driver heat sink.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...