Setup & Operation 12. Option Units
108
RC180 Rev.17
Input Signal
Bit No.
Input Signal
Bit No.
Start
512
ForcePowerLow
Not Set
SelProg1
513
Reserved
Not Set
SelProg2
514
ExtCmdSet
Not Set
SelProg4
515
ExtRespGet
Not Set
Stop
516
ExtCmdReset
Not Set
Pause
517
Alive
Not Set
Continue
518
Reset
519
SetMotorsOn
520
SetMotorsOff
521
Home
522
Output Signal
Bit No.
Input Signal
Bit No.
Ready
512
InsideBox1
Not Set
Running
513
InsideBox2
Not Set
Paused
514
InsideBox3
Not Set
Error
515
InsideBox4
Not Set
EStopOn
516
InsideBox5
Not Set
SafeguardOn
517
InsideBox6
Not Set
SError
518
InsideBox7
Not Set
Warning
519
InsideBox8
Not Set
MotorsOn
520
InsideBox9
Not Set
AtHome
521
InsideBox10
Not Set
CurrProg1
522
InsideBox11
Not Set
CurrProg2
523
InsideBox12
Not Set
CurrProg4
524
InsideBox13
Not Set
AutoMode
525
InsideBox14
Not Set
TeachMode
526
InsideBox15
Not Set
PowerHigh
Not Set
InsidePlane1
Not Set
ErrorCode1
527
InsidePlane2
Not Set
ErrorCode2
528
InsidePlane3
Not Set
ErrorCode4
529
InsidePlane4
Not Set
ErrorCode8
530
InsidePlane5
Not Set
ErrorCode16
531
InsidePlane6
Not Set
ErrorCode32
532
InsidePlane7
Not Set
ErrorCode64
533
InsidePlane8
Not Set
ErrorCode128
534
InsidePlane9
Not Set
ErrorCode256
535
InsidePlane10
Not Set
ErrorCode512
536
InsidePlane11
Not Set
ErrorCode1024
537
InsidePlane12
Not Set
ErrorCode2048
538
InsidePlane13
Not Set
ErrorCode4096
539
InsidePlane14
Not Set
ErrorCode8192
540
InsidePlane15
Not Set
Reserved
Not Set
Alive
Not Set
ExtCmdGet
Not Set
ExtRespSet
Not Set
ExtCmdResult
Not Set
ExtError
Not Set
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...