Maintenance 6. Maintenance Parts Replacement Procedures
154
RC180 Rev.17
Motor Driver
(Axis 5 and 6)
Mount
(1) Insert the Motor Driver along the guide
rails until the surface height differences
of the Motor Driver comes to 5 mm or
less.
A
5mm or less
Top Surface of
Motor Drive
(2) Push the Motor Driver securely into the
two Motor Driver connectors.
(3) Secure the Motor Driver mounting bracket with two screws.
(4) Secure the top cover of the ProSix Driver Unit with four screws.
(5) Close the front side.
Refer :
Maintenance 6.3.2 Replacing Motor Driver (Axis 1 to 4)
Mounting procedure from (5) to (9)
(6) Plug in the power connector. Turn ON the Controller and make sure that the
Controller starts properly without any vibration or abnormal noise.