Maintenance 8. Trouble Shooting
RC180 Rev.17
207
No.
Message
Remedy
Note 1
Note 2
3234
Port number was not specified.
Port number that indicates the file or
communication port is not specified in
Read, ReadBin, Write, and WriteBin
statements.
Refer to
SPEL+ Language Reference
“
Read Statement
” and specify a proper
file number or port number.
3235
String type variable was not specified.
String type variable is not specified in
the command that requires specification
of string type variable as a parameter.
Specify a valid string type variable.
3236
RS-232C port number was not
specified.
RS-232C port number is not specified in
OpenCom, CloseCom, and SetCom
statements. Refer to
SPEL+ Language
Reference
“
OpenCom Statement
” and
specify a proper port number.
3237
Network communication port number
was not specified.
Network communication port number is
not specified in OpenNet, CloseNet,
SetNet, and WaitNet
statement.
Specify an integer from 201 to 216.
3238
Communication speed was not
specified.
Communication speed (baud rate) is not
specified in SetCom statement. Refer
to
SPEL+ Language Reference “SetCom
Statement”
and specify a proper baud
rate.
3239
Data bit number was not specified.
Data bit length is not specified in
SetCom statement. Refer to
SPEL+
Language Reference
“SetCom
Statement”
and specify a proper data bit
length.
3240
Stop bit number was not specified.
Stop bit length is not specified in
SetCom statement. Refer to
SPEL+
Language Reference
“SetCom
Statement”
and specify a proper stop bit
length.
3241
Parity was not specified.
Parity is not specified in SetCom
statement. Refer to
SPEL+ Language
Reference
“SetCom Statement”
and
specify a proper parity.
3242
Terminator was not specified.
Terminator (end of send/receive line) is
not specified in SetCom and SetNet
statements. Refer to
SPEL+ Language
Reference
“SetCom Statement”
and
specify a proper terminator.
3243
Hardware flow was not specified.
Hardware flow is not specified in
SetCom statement. Refer to
SPEL+
Language Reference
“SetCom
Statement”
and specify a proper flow
control.
3244
Software flow was not specified.
Software flow is not specified in SetCom
statement. Refer to
SPEL+ Language
Reference
“SetCom Statement”
and
specify a proper flow control.
3245
None was not specified.
“NONE” is not specified for software
flow control setting in SetNet statement.
Specify “NONE”.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...