127
4.3 Backup
Backup the Controller status from the Teach Pendant (Option) or EPSON RC+ 5.0.
4.3.1 Backup from EPSON RC+ 5.0
(1)
Select EPSON RC+ 5.0 menu-[Tools]-[Controller] to display the [Controller Tools]
dialog.
(2)
Click the <Backup Controller…> button to display the [Browse For Folder] dialog.
(3)
Specify the folder to save the backup data. Create a new folder if desired.
(4)
Click the <OK> button. A folder is created in the specified folder containing the
backup data with a name in the following format.
B_ serial number_date status was saved
→
Example: B_12345_200608074410
(5)
The following message appears when backup is completed.
(6)
Click the <OK> button to complete the backup.
CAUTION
■
Do not edit the backup files. Otherwise, operation of the robot system after data
restoration to the Controller is not assured.
Summary of Contents for RC180