No.
Message
Remedy
Note 1
Note 2
1037
Cannot execute in Remote Ethernet
enable except from the Remote
Ethernet.
The command cannot be executed by the
console except the remote Ethernet when
Auto flag of the remote Ethernet is ON.
1040
Cannot execute in Remote RS232C
enable except from the Remote
RS232C.
1041
Cannot execute during Emergency
Stop status.
Cancel the Emergency Stop status.
1042
Cannot execute while the safeguard is
open.
Close the safeguard.
1043
Cannot execute during error condition.
Cancel the error condition.
1044
Cannot execute when the remote pause
input is ON.
Change the remote pause input to OFF.
1045
Input waiting condition is the only
available condition to input.
The controller received an input while it
was not in the Input waiting condition.
1046
Cannot execute during file transfer.
Execute after the file transmission.
1047
Cannot cancel the command executed
from other devices.
Cancel the motion command from the
device the command was issued from.
1048
Cannot execute after after low voltage
was detected.
Reboot the controller.
1049
Other devices are in program mode.
1050
Password is too long.
Enter the password that is less than 16
characters.
1051
Export Controller Status failed.
1.
Retry using the same USB
memory.
2.
Retry using another USB
memory.
3.
Retry after rebooting the
controller.
1052
Export Controller Status busy.
Execute the command after completing
the controller status backup.
1100
File failure. Cannot access the file.
1.
Reboot the controller.
2.
Reinstall the firmware.
3.
Replace the CF.
1102
File failure. Read and write failure of
the registry
1.
Reboot the controller..
2.
Replace the CF.
1103
File is not found.
Check whether the file exists.
1104
Project file was not found.
Rebuild the project.
1105
Object file was not found.
Rebuild the project.
1106
Point files were not found.
Rebuild the project.
1107
The program is using a feature that is
not supported by the current controller
firmware version.
1108
One or more source files are updated.
Please build the project.
Rebuild the project.
1109
Not enough storage capacity.
Increase free space of the USB memory.
1110
File is not found.
1120
File failure. Setting file is corrupt.
Restore the controller configuration.
1121
File failure. Project file is corrupt.
Rebuild the project.
1122
File failure. Point file is corrupt.
Rebuild the project.
1123
File failure. I/O label file is corrupt.
Rebuild the project.
1124
File failure.
User error file is corrupt.
Rebuild the project.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...