Setup & Operation 12. Option Units
110
RC180 Rev.17
12.4.2 Board Setup (RS-232C)
Board Appearance
Switch and Jumper Configuration
CN1
CN2
CN3
CN4
JMP1
DSW2
DSW1
CN6
Set DSW1, DSW2 and JMP1.
CN6 is all open.
1
st
board
2
nd
board
SW4
SW3
SW2
SW1
DS
W
2
ON
123
4
SW8
SW7
SW6
SW5
SW4
SW3
SW2
SW1
123
45
67
8
ON
DS
W
1
IRQ15
IRQ11
IRQ10
IRQ7
IRQ5
JMP
1
JP5
JP4
JP3
JP2
JP1
1 2
CN6
1
2
9
10
SW4
SW3
SW2
SW1
DS
W
2
ON
123
4
SW8
SW7
SW6
SW5
SW4
SW3
SW2
SW1
123
45
67
8
ON
DS
W
1
IRQ15
IRQ11
IRQ10
IRQ7
IRQ5
JMP
1
JP5
JP4
JP3
JP2
JP1
1 2
CN6
1
2
9
10
12.4.3 Verify with EPSON RC+ 5.0 (RS-232C)
When an RS-232C board is mounted in as option unit, the Controller software
automatically identifies the RS-232C board. Therefore, no software configuration is
needed. Correct identification can be confirmed from EPSON RC+ 5.0.
(1)
Select the EPSON RC+ 5.0 menu-[Setup]-[Controller] to display the [Setup
Controller] dialog.
(2)
Select the [RS-232C].
If no RS-232C board is identified, RS-232C will not be displayed.
If RS-232C is displayed, then the Controller software identified the RS-232C board.
Communication with external equipment is available.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...