Maintenance 8. Trouble Shooting
RC180 Rev.17
235
Vision
No.
Message
Remedy
Note 1
Note 2
7300
Vision Communication.
Server mode not supported.
7302
Vision Communication.
Failed to read from the camera.
Check the connection with the camera.
7303
Vision Communication.
Read data overflow.
Data exceeding the receive buffer was
received.
7304
Vision Communication.
Failed to open the Ethernet port.
Check the connection with the camera.
7305
Vision Communication.
Invalid IP address of camera.
Rebuild the project. Check the camera
configuration.
7306
Vision Communication. No
specification of Server/Client.
7307
Vision Communication.
Failed to send to the camera.
Check the connection with the camera.
7308
Vision Communication.
Camera version is old.
The version of the connected camera is
old. Update the camera.
7321
Vision Communication.
Camera setting has not been set.
Rebuild the project. Check the camera
configuration.
7322
Vision Communication.
Read timeout.
Check the connection with the camera.
7323
Vision Communication.
Read invalid data.
Check the connection with the camera.
7324
Vision Communication.
Failed to send to the camera.
Check the connection with the camera.
7325
Vision Communication.
Connection is not completed.
Check the connection with the camera.
7326
Vision Communication.
Read data is too long.
7327
Vision Communication.
Undefined vision sequence.
Check the sequence name.
7328
Vision Communication.
Camera setting has not been set.
Rebuild the project. Check the camera
configuration.
7329
Vision Communication.
Vis file is not found.
Rebuild the project. Check the camera
configuration.
7330
Vision Communication.
Failed to allocate memory.
Reduce the number of sequences,
objects, and calibration.
7341
Vision Communication.
Out of max camera number.
Review the camera registration.
7342
Vision Communication.
Invalid camera number.
Review the camera registration.
7343
Vision Communication.
VSet parameter is too long.
Review the names and string variables of
sequences, objects, and calibration.
7344
Vision Communication:
Too many parameters for VGet.
The number of specified variables is
exceeding 32. Reduce the number of
parameters.
7345
Vision Communication.
Not enough data for VGet statement
variable assignment.
Reboot the camera.
Check the version of the camera.
7346
Vision Communication.
Cannot execute a Vision statement
from the command window.
Execute the command from the program.
7500
Smart camera. Out of memory.
Initialize the camera.
Reduce the project size.
7501
Smart camera. Project does not exist.
Rebuild the project.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...