Maintenance 6. Maintenance Parts Replacement Procedures
RC180 Rev.17
157
CPU Board Unit
Mount
(1) Connect the four CPU board connectors.
Refer :
Maintenance 3.2 Diagram of Cable Connections
- Cable Layout Drawing
(2) Carefully insert the CPU board unit by
pushing it straight in.
Make sure that connector CN2 of the
CPU Board and the DMB connector
(CPU IF) are connected when inserting
the Unit.
Be sure to keep the cable from being
trapped or damaged.
(3) Mount the screw on each side of the CPU board.
Connected to the C3 or S5 series manipulator
Perform steps (4) to (6) to secure the ProSix Driver Unit.
Connected to the G or RS series manipulator
Move on to step (7).
(4) Insert the ProSix Driver Unit into the
position.
Refer to the photo and be sure to
position the mounting bracket properly
as shown.
ProSix
Driver Unit side
(5) Secure the ProSix Driver Unit with two screws on the top and bottom.
(6) Secure the two covers with a screw of the top and bottom.
(7) Secure each cover with the screws.
(Front cover : 4 screws, Backside : 3 screws)
(8) Connect the following cables to the CPU board.
USB PC LAN USB memory TP/OP I/O
(9) Plug in the power connector. Turn ON the Controller and make sure that the
Controller starts properly without any vibration or abnormal noise.
NOTE
NOTE
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...