Maintenance 8. Trouble Shooting
RC180 Rev.17
177
No.
Message
Remedy
Note 1
Note 2
1521
Vision communication.
Failed to initialize Ethernet.
Reboot the controller.
1522
Vision communication.
Failed to terminate Ethernet.
1523
Vision communication.
Failed to create the socket handle.
Reboot the controller.
1524
Vision communication.
Failed to connect.
Check the connection between the
camera and controller.
1526
Vision communication.
Failed to send to the server.
Check the connection between the
camera and controller.
1527
Vision communication.
Failed to read from the server.
Check the connection between the
camera and controller.
1528
Vision communication.
Failed to set option.
1529
Vision communication.
Ethernet has not been initialized yet.
Reboot the controller.
1530
Vision communication.
Connection is not completed.
Check the connection of the camera and
controller.
1531
Vision communication.
All sockets are used.
1532
Vision communication.
Send timeout.
Check the connection between the
camera and controller.
1533
Vision communication.
Read timeout.
Check the connection between the
camera and controller.
1534
Vision communication.
Communication error.
Check the connection between the
camera and controller.
1550
Communication failure.
Ethernet initialization error.
Reboot the controller. Check the
connection of the Ethernet cable.
1551
Communication failure.
USB initialization error.
Reboot the controller. Check the
connection of the USB cable.
1552
Communication failure. Controller
internal communication error.
Reboot the controller.
1553
Communication failure. Invalid data is
detected.
1555
Ethernet transmission error.
Check the connection between the PC
and controller.
1556
Ethernet reception error.
Check the connection between the PC
and controller.
If the router is used between the PC and
controller, confirm that the DHCP
function is disabled.
1557
USB transmission error.
Check the connection between the PC
and controller.
1558
USB reception error.
Check the connection between the PC
and controller.
1559
Communication failure. Failed to
allocate memory.
1580
Parser communication error.
1.
Reboot the controller.
2.
Upgrade the firmware.
1581
Parser communication failure. Timeout
error occurred during communication
with parser.
1.
Reboot the controller.
2.
Reinstall the firmware.
1582
Parser communication failure. Parser
transmission error.
Reboot the controller.
Rebuild the project.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...