Maintenance 8. Trouble Shooting
RC180 Rev.17
227
No.
Message
Remedy
Note 1
Note 2
5040
Motor torque output failure in high
power state. Check the power cable
connection, the robot, the driver or the
motor.
Specify the Weight/Inertia setting.
Check the load.
Check the robot. (Smoothness, backlash,
non-smooth motion, loose belt tension,
brake)
Check the interference with the
peripheral equipment. (Collision,
contact)
Check the model setting.
Check the power cable connection.
Check the robot power wiring. (Missing
pin, disconnection, short-circuit)
Check the power supply voltage. (Low
power supply voltage)
Replace the motor driver.
Replace the DMB.
Replace the motor.
5041
Motor torque output failure in low
power state. Check the power cable
connection, robot, brake, driver, or
motor.
Check the robot. (Smoothness, backlash,
non-smooth motion, loose belt tension,
brake)
Check the interference with the
peripheral equipment. (Collision,
contact)
Check the model setting.
Check the power cable connection.
Check the robot power wiring. (Missing
pin, disconnection, short-circuit)
Check the power supply voltage. (Low
power supply voltage)
Replace the motor driver.
Replace the DMB.
Replace the motor.
5042
Position error overflow in high power
state. Check the power cable
connection, the robot, the driver and
the motor.
Specify the Weight/Inertia setting.
Check the load.
Check the robot. (Smoothness, backlash,
non-smooth motion, loose belt tension,
brake)
Check the interference with the
peripheral equipment. (Collision,
contact)
Check the model setting.
Check the power cable connection.
Check the robot power wiring. (Missing
pin, disconnection, short-circuit)
Check the power supply voltage. (Low
power supply voltage)
Replace the motor driver.
Replace the DMB.
Replace the motor.
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...