Maintenance 5. Firmware Update
RC180 Rev.17
139
5.4 Firmware Initialization Procedure
The firmware initialization procedure described in this section.
(1)
Connect the development PC to the Controller with a USB cable (the firmware
cannot be changed with an Ethernet connection).
(2)
Turn ON the Controller. Do not start the development software EPSON RC+ 5.0
until firmware initialization is complete.
(3)
Insert the “firmware CD-ROM” in the development PC CD-ROM drive.
(4)
Execute “Ctrlsetup.exe”.
(5)
Select the <Initialize> option button and click the <Next> button.
(6)
Make sure that the development PC is connected to the Controller with a USB cable
and Click the <Next> button.
(7)
Check the version information and click the <Install> button.