Maintenance 6. Maintenance Parts Replacement Procedures
164
RC180 Rev.17
6.7.4 Mount Option Unit 2
When adding Option Unit 2:
Perform steps (1) to (8).
When replacing Option Unit 2:
Perform steps (3) to (7).
(1) Remove the fan filters (two places) of Option Unit 1 and mount Option Unit 2.
Refer :
Maintenance 6.1.3 Cleaning and Replacing Fan Filter
(2) Secure the Option Unit mounting
brackets to Option Unit 1 with four
screws.
The shape of the mounting bracket for
the top (DPB) and bottom (CPU board)
side are different. Be sure to mount
them properly.
Top (DPB) Side
Bottom (CPU Board) Side
(3) Secure Option Unit 2 with two screws each on front and backside.
(4) Remove two screws to remove the backside cover of the Option Unit 1.
(5) Connect the flat cable connectors (two places)
to the backside of Option Units 1 and 2.
Connecting Connector
Option Unit 1
Option Unit 2
Back of Controller
Main Part
(6) Secure the covers to the backside of Option
Units 1 and 2 with two screws for each.
Orient the cover so that there is no gap when
mounted.
(7) Plug in the power connector. Turn ON the Controller and make sure that the
Controller starts properly without any vibration or abnormal noise.
NOTE
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...