background image

T1VK3F4

4 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  Trove1 enclosure with TV1 Altronix/HID VertX

®

 backplane

  -  One (1) eFlow6NB - Power Supply/Charger

  -  One (1) VR6 - Voltage Regulator

  -  One (1) PDS8 - Dual Input Fused Power Distribution Module

T2VK7F8

8 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  Trove2 enclosure with TV2 Altronix/HID VertX

®

 backplane

  -  One (1) eFlow104NB - Power Supply/Charger

  -  One (1) ACM8 - Fused Access Power Controller

  -  One (1) VR6 - Voltage Regulator

  -  One (1) PDS8 - Dual Input Fused Power Distribution Module

T3VK75F20

20 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  Trove3 enclosure with TV3 Altronix/HID VertX

®

 backplane

  -  One (1) eFlow104NB - Power Supply/Charger

  -  One (1) eFlow102NB - Power Supply/Charger

  -  Two (2) ACM8 - Fused Access Power Controllers

  -  One (1) ACM4 - Fused Access Power Controller

  -  One (1) PD8UL - Fused Power Distribution Module

  -  One (1) RSB2 - Rocker Switch Bracket with Two (2) Rocker Switches

Access & Power Integration

Rev. TVK_042519

Installing Company:  _____________________ Service Rep. Name:  __________________________________________ 

Address:  ________________________________________________________  Phone #:  _________________________

All registered trademarks are property of their respective owners. 

More than just power.™

Installation Guide

Summary of Contents for Trove T1VK3F4

Page 1: ...5F20 20 Door Kit with Fused Outputs Fully assembled kit includes Trove3 enclosure with TV3 Altronix HID VertX backplane One 1 eFlow104NB Power Supply Charger One 1 eFlow102NB Power Supply Charger Two 2 ACM8 Fused Access Power Controllers One 1 ACM4 Fused Access Power Controller One 1 PD8UL Fused Power Distribution Module One 1 RSB2 Rocker Switch Bracket with Two 2 Rocker Switches Access Power Inte...

Page 2: ...he National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in the wall to line up with the top two three keyholes in the enclosure Install two three upper fasteners and screws in the wall with the screw heads protruding Place the enc...

Page 3: ...m Mounting V100 V200 V300 V1000 V2000 A NC C NO NC C NO AC FAIL BAT FAIL TRIGGER AC DC AC1 EOL NO GND SUPERVISED RESET AUX BAT DC L G N OFF 24V ON 12V ON Altronix eFlow6NB INP1 DM1 OFF IN1 IN2 Out1 1 off 2 DM1 DM2 DM2 Common Common INP2 IN2 Fuse IN1 Fuse Common Power Outputs NEG N P OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 1 2 3 4 5 6 7 8 10 10 3 3 3 3 3 3 3 3 Out2 1 off 2 Out3 1 off 2 Out4 1 off 2...

Page 4: ...NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT TRIGGER 10A 250V INP T RET NO C NC FACP INTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 O N 1 2 3 4 O N Altronix ACM8 INP1 DM1 OFF IN1 IN2 Out1 1 off 2 DM1 DM2 DM2 Common Common INP2 IN2 Fuse IN1 Fuse Common Power Outputs...

Page 5: ...P 1 2 3 4 O N 1 2 3 4 O N Altronix ACM8 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT TRIGGER 10A 250V INP T RET NO C NC FACP INTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 O N ...

Page 6: ... 5 321 31mm 13 0 330 2mm 1 45 36 83mm 7 25 184 15mm 4 5 114 3mm 4 5 114 3mm 4 5 114 3mm 2 75 69 85mm 1 25 31 75mm 1 5 38 09mm 8 5 215 9mm 18 0 457 2mm 0 5897 14 98mm 1 0958 27 83mm 0 6012 15 27mm 6 5 165 1mm 1 25 31 75mm 1 25 31 75mm 1 5 38 09mm 8 5 215 9mm 6 5 165 1mm 0 569 14 52mm 1 948 49 483mm 1 115 28 32mm 1 362 34 59mm ...

Page 7: ...5mm 8 25 209 54mm 8 00 203 2mm 1 5 38 1mm 1 25 31 75mm 0 85 21 59mm 0 85 21 59mm 1 00 25 4mm 2 00 50 8mm 1 25 31 75mm 2 00 50 8mm 2 00 50 8mm 5 25 133 35mm 5 25 133 35mm 7 00 177 79mm 2 00 50 8mm 2 00 50 8mm 27 00 685 8mm 3 50 88 9mm 0 5625 14 29mm 2 415 61 34mm 0 685 17 399mm 1 77 44 96mm 3 50 88 9mm 21 50 546 1mm 19 80 502 92mm 5 25 133 35mm 5 25 133 35mm 0 885 22 479mm 1 125 28 32mm Knockouts ...

Page 8: ...14 01 355 9mm 9 5 241 3mm 1 25 31 75mm 1 55 39 37mm 1 78 45 21mm 1 25 31 8mm 1 07 27 2mm 1 10 27 9mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 36 12 917 5mm 33 63 854 20mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altronix com...

Reviews: