Maintenance 6. Maintenance Parts Replacement Procedures
RC180 Rev.17
159
6.6 Fuse
The fuse is not used for RC180-UL.
Fuse
Remove
(1) Turn OFF the Controller and unplug the power connector.
(2) Remove the Option Unit when it is mounted.
Refer :
Maintenance 6.7.2 Remove Option Unit 1
Maintenance 6.7.5 Remove Option Unit 1, 2
(3) Remove the fan unit
Refer :
Maintenance 6.1.2 Replacing Fan Unit
(4) Remove the Motor Drive Module.
Refer :
Maintenance 6.3.2 Replacing Motor Driver (Axis 1 to4)
(5) Remove four screws on the intermediate
plate as shown.
Intermediate
Plate
(6) Remove the FG mounting screws
(G, RS: 2 screws/ C3, S5: 3 screws)
and remove the plate.
Be sure to remove the intermediate plate
slowly.
The cables are connected to the main
chassis.
Intermediate
Plate
C3, S5
(3 screws)
FG Mounting Screw
G, RS
(2 screws)
WARNING
■
Before disconnecting the DPB cable connector, always make sure that the power
supply of the Controller is unplugged. Performing this procedure while the
power supply is connected is extremely hazardous and may result in electric
shock and/or cause serious safety problems.
NOTE
NOTE