No.
Message
Remedy
Note 1
Note 2
2320
Function failure. Argument type does
not match.
Rebuild the project.
2321
Function failure. Return value does not
match to the function.
Rebuild the project.
2322
Function failure.
ByRef type does not match.
Rebuild the project.
2323
Function failure. Failed to process the
ByRef parameter.
Rebuild the project.
2324
Function failure. Dimension of the
ByRef parameter does not match.
Rebuild the project.
2325
Function failure. Cannot use ByRef in
an Xqt statement.
Rebuild the project.
2326
Cannot execute a Dll Call statement
from the command window.
Execute DII Call from the program.
2327
Failed to execute a Dll Call.
Check the DLL.
Review the program.
2328
Cannot execute the task before connect
with RC+.
You need to connect with RC+ before
executing the task.
2329
Cannot execute a Eval statement in a
Trap Call process.
Check the program.
2330
Trap failure.
Cannot use the argument in Trap Call
or Xqt statement.
Check the program.
2331
Trap failure. Failed to process Trap
Goto statement.
Rebuild the project.
2332
Trap failure. Failed to process Trap
Goto statement.
Rebuild the project.
2333
Trap failure. Trap is already in process.
Rebuild the project.
2334
Cannot execute a Eval statement in a
Trap Finsh and Trap Abort process.
Check the program.
2335
Cannot continue execution and Reset
Error in TEACH mode.
Check the program.
2336
Cannot use Here statement with a
parallel process.
Go Here :Z(0) ! D10; MemOn(1) !
is not executable.
Change the program to:
P999 = Here
Go P999 Here :Z(0) ! D10; MemOn(1) !
2337
Cannot execute except from the event
handler function of GUI Builder
Review the program.
2340
Value allocated in InBCD function is
an invalid BCD value.
Review the program.
Tens digit
Units digit
2341
Specified value in the OpBCD
statement is an invalid BCD value.
Review the program.
The specified
value
2342
Cannot change the status for output bit
configured as remote output.
Check the remote I/O setting.
I/O number
1: bit, 2: byte,
3: word
2343
Output time for asynchronous output
commanded by On or Off statement is
out of the available range.
Review the program.
The specified
time
2344
I/O input/output bit number. is out of
available range or the board is not
installed.
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Bit number
Summary of Contents for RC180
Page 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Page 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Page 13: ...Safety This section contains information for safety of the Robot System ...
Page 14: ......
Page 20: ......
Page 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Page 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 126: ...114 ...